  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 132H5232

VACON 

VACON NXP Air Cooled AC Drive 250 kW 525-690V IP00 - 132H5232

The VACON NXP Air Cooled AC Drive with order code 132H5232 and type code NXP02616-G0N1SSF-A8AF0000C5+FL26+DLRU is a 250 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 132H3499

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 132H3499

The VACON NXP Air Cooled AC Drive with order code 132H3499 and type code NXP05906-A0N0SSG-ANAFB500C5 is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132H4487

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP21 - 132H4487

The VACON NXP Air Cooled AC Drive with order code 132H4487 and type code NXP04605-A2L0SSB-A1A200C300+FL23+GNCT+GNKC+GNUA+GNEA is a 250 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10...
VACON NXP Air Cooled AC Drive 132H3231

VACON 

VACON NXP Air Cooled AC Drive 7.5 kW 380-500V IP54 - 132H3231

The VACON NXP Air Cooled AC Drive with order code 132H3231 and type code NXP00165-A5H1SSV-A1A20000C3+DLES is a 7.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR05 configuration. It is...
VACON NXP Air Cooled AC Drive 132H3232

VACON 

VACON NXP Air Cooled AC Drive 18.5 kW 380-500V IP54 - 132H3232

The VACON NXP Air Cooled AC Drive with order code 132H3232 and type code NXP00385-A5H1SSS-A1A20000C3+DLES is a 18.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It is...
VACON NXP Air Cooled AC Drive 132H2936

VACON 

VACON NXP Air Cooled AC Drive 75 kW 380-500V IP54 - 132H2936

The VACON NXP Air Cooled AC Drive with order code 132H2936 and type code NXP01405-A5H0BSV-A1AF0000E9+QGLM+FL23+ASFRG001+DPAP+DLDE is a 75 kW (100 HP), three-phase 380-500 V supply, IP54 enclosure,...
VACON NXP Air Cooled AC Drive 132H2935

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP54 - 132H2935

The VACON NXP Air Cooled AC Drive with order code 132H2935 and type code NXP00315-A5H1SSV-A1AF0000E9+QGLM+FL23+ASFRG001+DPAP+DLDE is a 15 kW (20 HP), three-phase 380-500 V supply, IP54 enclosure,...
VACON NXP Air Cooled AC Drive 132H2629

VACON 

VACON NXP Air Cooled AC Drive 450 kW 380-500V IP00 - 132H2629

The VACON NXP Air Cooled AC Drive with order code 132H2629 and type code NXP08205-A0N0NSB-A1A200C200 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR12 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132H2168

VACON 

VACON NXP Air Cooled AC Drive 110 kW 380-500V IP21 - 132H2168

The VACON NXP Air Cooled AC Drive with order code 132H2168 and type code NXP02055-B2H0SSV-00AF0000C2 is a 110 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132H1323

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 132H1323

The VACON NXP Air Cooled AC Drive with order code 132H1323 and type code NXP03855-A0N0TSA-A1A20000C2+DLES is a 200 kW (300 HP), three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X2575

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1796 kW 525-690V IP00 - 137X2575

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X2575 and type code NXA17006-A0T02WG-A1A2000000+MASG+ARFIFF03 is a 1796 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X2654

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 103 kW 380-500V IP00 - 137X2654

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X2654 and type code NXA01685-A0T02WV-A8A2D7BHE9+MASG+ARFIFF03+GABV is a 103 kW, three-phase 380-500 V...